Egress Doors Building Code
Nfpa 101b code for means of egress for buildings and structures shall be known as the means of egress code is cited as such and shall be referred to herein as this code or the code 1 1 2 danger to life from fire.
Egress doors building code. This code addresses those egress features necessary to minimize danger to life from fire and smoke crowd pressures and movement of individuals and groups. When the sill height of an egress window is located below grade common for egress windows provided for a basement a window well must be provided. The exterior building entrance doors serving occupancies in group a b e m r 1 or r 2 and entrance doors to tenant spaces in occupancies in groups a b e m r 1 and r 2 are permitted to be equipped with an approved entrance and egress access control system which shall be installed in accordance with all of the following criteria. Egress window well code requirements.
Exterior doors in homes and businesses not only provide security but they also serve as a vital means of egress during a fire or other emergency. In most countries such doors are regulated by local building codes which stipulate how many doors are required and the requirements for each exit. The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. Doors are laid out so that they can be opened from the outside when the building is occupied.
Code change proposals to sections preceded by the designation f will be considered by the. Nfpa emergency exit door requirements for locks. While swinging the door should leave available at least half of the required width of a corridor hallway etc for use. Any other exterior door has a threshold height limited to 7 inches.
2018 irc section r311 3 1 restricts threshold height a required exit door in residences to 1 inches from the top of the the threshold to the floor or landing on each side of the door. Means of egress doors in the irc. Chapter 10 of this code is duplicated in chapter 10 of the international fire code. The means of egress is used in an exit enclosure or while serving a high hazard area.
An egress door is an exit designed to allow the occupants of a building to evacuate safely during an emergency. The area of a window well shall not be less than 9 square feet with a horizontal length width of no less than 36 inches. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.