Elevator Equipment Room Electrical Requirements
One 1 120v 15 amp fused disconnect or circuit breaker as outlined for cab lighting.
Elevator equipment room electrical requirements. Our power module switch is an all in one elevator disconnect switch available in configurations to meet virtually any single elevator shutdown and disconnect requirement. Elevator electrical requirements by general contractor owner each residential elevator requires three 3 items from your electrician and telecommunications contractor s. Size and configure the elevator machine room so that there is a minimum clearance of 18 between any building component and a traction elevator drive machine. The american society of mechanical engineers publishes the construction standards for elevator equipment rooms.
Article 620 covers the installation of electrical equipment and wiring used in connection with elevators dumbwaiters escalators moving walks platform lifts and stairway lifts. And as the designer you can become the fulcrum on which all of these. As they review the plans and the construction site they may have conflicting interpretations or requirements. New in 2019 if your elevator must meet a17 1 2019 there are some additional emergency communications requirements you will need to adhere to.
General electrical discussion business marketing and sales tools equipment and. G work space required in machine rooms and machinery spaces. The many codes and guidelines that regulate the electrical design of an elevator can seem overwhelming and dealing with the electrical inspector elevator inspector and fire marshal can be even more intimidating. They are as follows.
Provide a fused disconnect switch for each elevator in the control room located in a position based on local code and within sight of elevator equipment and arranged to be locked in the off position. When located within the machine room it shall be isolated from the elevator equipment by an enclosure conforming to section 3011 a. Wiring requirements are outlined in part iii of this article. A where mechanical ventilation equipment is provided it shall be located outside the elevator machine room where possible.
Easily selectively coordinated this switch meets all of the applicable code requirements for the elevator code fire alarm code and national electrical code nec. Elevator safety is a critical consideration for builders who have state safety codes to follow permits to obtain and regular inspections to pass. In traction elevator machine rooms install a beam above the elevator machine and motor that is sufficient in size and capacity to support the removal of elevator equipment. Elevator calls directed to a 24 hour live monitoring service that is able to respond to emergencies asme a17 1 section 2 27 note.
Control room must be of adequate size to provide clearances around and between equipment as required by code. Panels in elevator machine rooms.