Emergency Exit Light Testing Requirements
The test must include a thirty second test of the lights.
Emergency exit light testing requirements. The fire code requires that the emergency lights or lighted exit signs be inspected and tested at least once a month. Self luminous or electroluminescent signs that have a minimum luminance surface value of at least 06 footlamberts 0 21 cd m 2 are permitted. In the first 1 5 hours after a failure emergency lighting must provide an average of one foot candle and no less than 0 1 foot candle at any point along the path of egress. Testing requirements for emergency lighting section 7 9 3 of the life safety code addresses the nfpa s requirements for periodic testing of emergency lights.
The procedures of emergency light testing have been clearly set out in the as 2293 and failure to comply may lead to varying degrees of penalty. How to test exit lights australian standards require that exit lights be tested every 6 months and must remain illuminated for at least 90 minutes running on battery power. Once a year an outside party is required to come in to conduct a test on emergency and exit lighting. How long has it been since you tested your emergency lighting.
The fire code requires that the emergency lights or lighted exit signs be inspected and tested at least once a month. The regulations require that exit signs and illumination and emergency lighting get a 30 second test of their functionality and it is advised that written records be kept by the owner of these monthly inspections. Testing emergency lights emergency and exit lights are essential hence they require regular inspection testing and maintenance. Meet the code requirements or assume the risk emergency lighting including exit signage is subject to a 30 second test every month and an annual 90 minute test to ensure that the system will function correctly in the event of an emergency.
The test must include a thirty second test of the lights. The section acknowledges three different categories of emergency lights. The first step in emergency light testing will involve a full check of all of your emergency light products to ensure that they are compliant with as2293 3. To complete this test your tester will need to conduct.
Your emergency exit signs need to be submitted for a series of tests to ensure accordance with as nzs2293. Press this button and the lights will come on powered by the battery. Most emergency exit signs have a small push to test button on the casing. An annual test is also required with the lights being operated on emergency power for the full minimum of thirty minutes.
Traditional self testing self diagnostic and computer based self testing self diagnostic.